Free quote

Early design input

We'll review drawings and advise on opening sizes, systems, thresholds and recesses before anything is built.

Survey before order

Every structural opening is checked and measured on site before we order, so frames fit first time.

Our own fitters

Installed by our own experienced teams, not subcontracted, with a clean and tidy site.

Compliance covered

Systems chosen to meet Part L U-values, Part F ventilation and PAS 24 or Secured by Design where needed.

Technical data

Sliding door systems at a glance

SystemInterlockMax panelMax weightThermalSpec
Cortizo Cor Vision (InfiniGLIDE 3)20mm2500mm wide × 3000mm high320kgUw from 1.3 W/m²KPDF
GLIDE2121mm––Ask usPDF
EdgeGLIDE+35mm (typical)2200mm wide × 2600mm high240kgU-value from 1.2 W/m²KPDF
AluNet ESS47 Hybrid25mm super-slim or 50mm non-bonded––U-value 1.4 W/m²K, DER C ratingPDF
AluK BSC94 HI85mm standard · 45mm slim2000mm panel width × 3000mm frame height (2600mm high with security features)400kgU-value 1.7 W/m²K (double track, Ug 1.0) · DSER 'C' ratingPDF

Window systems at a glance

SystemFrame / profileSightlines / sashThermalSecuritySpec
AluK 58BW HI Casement58mm (70mm option)75mm frame to vent · 89mm frame to mullion · 43mm fixed light1.4 W/m²K double · 1.2 W/m²K triple · WER B–C · BRE Green Guide APAS 24 · Secured by Design · multi-point locking · Q-MarkPDF
AluK 58BW Flush HI70mm74mm frame to vent · 111mm vent to mullion to vent · 74mm dummy sash1.4 W/m²K double · 1.0 W/m²K triple · WER B–CPAS 24 · Secured by Design · multi-point locking · Q-MarkPDF
AluK 58BW TT HI58mm86mm frame to vent · 100mm frame to mullion · 43mm fixed light1.5 W/m²K double · 1.3 W/m²K triple · WER B–C · BRE Green Guide APAS 24 · Secured by Design · multi-point locking · Q-MarkPDF
Cortizo COR 70 Windows70mm frame and sash, 35mm polyamide thermal break66mmUw from 0.84 W/m²KPAS 24PDF
AluK Heritage Windows58mm or 70mm43mm fixed light · 66mm frame to vent · 81mm vent to mullion1.4 W/m²K double (Ug 1.0) · 1.1 W/m²K triple (Ug 0.7) · WER A–B · BRE Green Guide APAS 24 · Secured by Design · Q-Mark · multi-point lockingPDF
Kömmerling C7070mm, five chambers, chamfered–1.4 W/m²K double glazed · 1.2 W/m²K with Low-E Plus · A rated, A+ with 40mm tripleMulti-point locking · PAS 24:2022 and Secured by Design upgrade (Document Q)PDF
Kömmerling O70 & Legacy70mm, five chambers, fully sculptured ovolo–1.4 W/m²K double glazed · 1.2 W/m²K with Low-E Plus · A rated, A+ with 40mm tripleMulti-point locking · PAS 24:2022 and Secured by Design upgrade (Document Q)PDF
Liniar EnergyPlus70mm, six symmetrical chambers, sculptured or chamfered–U-value as low as 0.8 W/m²K with triple glazing · WER up to A++ without low-iron glass or thermal insertsMulti-point locking as standard · PAS 24 · Secured by Design · BBA approvedPDF
Timberlook Flush Sash70mm40mm outer frame + 5mm gap + 58mm sash · 30mm transom/mullionU-value 1.4 W/m²K standard · 1.2 W/m²K with Planitherm 1 · WER AYale shootbolt locking · PAS 24 with uprated glass and hardware · Document QPDF
Roseview Ultimate Rose137mm–1.5 W/m²K standard (A rated) · 1.4 with upgraded glass · 1.2 with ThermoVFlexSteel-reinforced sashes · Secured by Design / PAS 24:2022 / Part Q optionPDF

Manufacturer data. Limits depend on size, glass and configuration. We confirm everything for your project.

Detailing

Getting large glazing right

The details that make the difference on site. Talk to us before these are fixed in the design.

Concealed frames

Cor Vision frames can be recessed into floor, walls and ceiling; GLIDE21 has a fully concealed frame. Recess depths and finishes need designing into the structure.

Thresholds & floor levels

Plan finished floor levels around the door. GLIDE21 is flush internally as standard; Cor Vision has a 44mm threshold. Drainage must be detailed outside.

Structural openings

Large sliding panels need a stiff head. Too much deflection and panels can bind. For oversize spans and post-free corners we work with your engineer on steel or portal frames.

Panel weights & access

Single panels can weigh 250–450kg. Plan delivery routes, lifting and access before install day.

Ventilation (Part F)

Large sliders often can't take trickle vents. Plan background ventilation elsewhere, such as in the windows or a mechanical system.

Overheating & solar gain

Large south and west-facing glazing may need solar control glass such as COOL-LITE SKN II to manage overheating on new builds.

Got a project on the drawing board?

Send us plans, elevations or a schedule and we'll come back with recommendations and a detailed quote.

Send us your drawings